TA3000 Power Measurement Standard
The TA3000 is a high-precision wideband AC parametric measurement standard. It is capable of simultaneously measuring multiple electrical parameters in an AC loop, including AC voltage, AC current, frequency, phase, harmonics, active/reactive/apparent power and energy, and power factor. This makes it ideal for calibration and testing of AC measuring instruments and power meters in laboratories and industrial environments.
Key Features
- High-precision wideband AC measurement.
- Simultaneous measurement of voltage, current, frequency, phase, and power parameters.
- Measures active, reactive, and apparent power and energy.
- Power factor and harmonic measurement capability.
- Low temperature coefficient for stable measurements.
- Ideal for laboratory calibration and verification of AC instruments.
AC Voltage Measurement
| Range | Resolution | Measurement Uncertainty (k=2) (ppm*RD + ppm*RG) | Temperature Coefficient @ (15~30)°C (ppm*RD + ppm*RG)/°C |
|---|---|---|---|
| 12 V | 10 μV | 45 ≤ F < 80 Hz: 30 + 20 80 ≤ F < 200 Hz: 90 + 60 200 ≤ F < 400 Hz: 150 + 100 400 ≤ F < 1 kHz: 450 + 300 |
1 + 0.5 |
| 60 V | 10 μV | 45 ≤ F < 80 Hz: 30 + 20 80 ≤ F < 200 Hz: 90 + 60 200 ≤ F < 400 Hz: 150 + 100 400 ≤ F < 1 kHz: 450 + 300 |
1 + 0.5 |
| 120 V | 0.1 mV | 45 ≤ F < 80 Hz: 30 + 20 80 ≤ F < 200 Hz: 90 + 60 200 ≤ F < 400 Hz: 150 + 100 400 ≤ F < 1 kHz: 450 + 300 |
1 + 0.5 |
| 240 V | 0.1 mV | 45 ≤ F < 80 Hz: 30 + 20 80 ≤ F < 200 Hz: 90 + 60 200 ≤ F < 400 Hz: 150 + 100 400 ≤ F < 1 kHz: 450 + 300 |
1 + 0.5 |
| 600 V | 0.1 mV | 45 ≤ F < 80 Hz: 30 + 20 80 ≤ F < 200 Hz: 90 + 60 200 ≤ F < 400 Hz: 150 + 100 400 ≤ F < 1 kHz: 450 + 300 |
1 + 0.5 |