UC9801A-01B-01C Hipot Tester
Models:
UC9801A (AC) | UC9801B (AC/DC) | UC9801C (AC/DC/IR)
UC9801 series program-controlled safety testers support AC withstand voltage, DC withstand voltage, and insulation resistance (IR) testing. Equipped with a new generation ARM processor and 480×272 LCD, these testers feature multi-step list display, keyboard lock, and automatic save of test conditions. Fast voltage rise (≤0.2s), open/short circuit detection (OSC), automatic discharge, and body protection against electric shock make it safe and efficient for lab and production use.
Performance Features
- Multi-step results displayed on a single screen
- Keyboard lock function and automatic save of test settings
- Short voltage rise time (≤0.2s)
- Open and short circuit detection (OSC)
- Automatic discharge after testing
- Current base reset function
- Support for U disk and internal file storage
- RS232 and Handler interface for automated test systems
- Optional RS485 interface for networked MODBUS communication
Technical Specifications
| Model | Measurement Parameter | AC Voltage Range | DC Voltage Range | Leakage Current | Voltage Rise Time | Test Time Setting | Arc Detection | Insulation Resistance |
|---|---|---|---|---|---|---|---|---|
| UC9801A | ACV | 50V–5kV, ±2% | — | 0.001mA–12mA, ±2% | 0.1s–999.9s | 0.1s–999.9s or continuous | 1–9 grade | — |
| UC9801B | ACV/DCV | 50V–5kV, ±2% | 50V–6kV, ±2% | AC: 0.001mA–12mA, ±2%; DC: 0.001mA–5mA, ±2% | 0.1s–999.9s | 0.1s–999.9s or continuous | 1–9 grade | — |
| UC9801C | ACV/DCV/IR | 50V–5kV, ±2% | 50V–6kV, ±2% | AC: 0.001mA–12mA, ±2%; DC: 0.001mA–5mA, ±2% | 0.1s–999.9s | 0.1s–999.9s or continuous | 1–9 grade | 50V–1kV DC, 100kΩ–50GΩ |
Other Features
- Memory: 100 groups of stored test settings
- Comparator: Upper/lower limit with sound and light alarms
- Trigger Modes: Internal, external (optional)
- Interface: RS232C, Handler
- Power Supply: 198–240VAC, 50Hz, Maximum 100VA
- Dimension (L×W×H): 374×208×99 mm | Weight: 7.5kg
Accessories
- Standard: UC8803 HV test clamp
- Optional: UC8804 HV test rod, UC6801-01 Foot switch