TI5000 DC Current Sensor Testing Device
TI5000 DC Current Sensor Testing Device

TI5000 DC Current Sensor Testing Device

TI5000 is a multifunctional testing system designed to evaluate the measurement performance of DC current sensors. The system integrates a DC high-current standard source, sensor output power measurement module, auxiliary power supply, customized sensor testing fixtures, computer workstation, test bench, and dedicated automated software.

The configuration can be customized according to user requirements, including output current range, accuracy class, number of sensor units supported, and required testing features. The TI5000 provides reliable and precise testing capabilities suitable for laboratory environments, manufacturing, calibration centers, and research applications.

Technical Specifications

Parameter Specification
Current Range 1 A, 2 A, 5 A, 10 A, 20 A, 50 A, 100 A, 200 A, 500 A… N kA (optional)
Output Range (10% ~ 120%) × RG (relay program-controlled switching)
Accuracy Class Class 0.01
Class 0.02
Class 0.05
Short-term Stability (% × RG/min) 0.003 (Class 0.01)
0.005 (Class 0.02)
0.01 (Class 0.05)
Measurement Uncertainty (k=2)
(% × RD + % × RG)
Class 0.01: 0.006 + 0.004
Class 0.02: 0.012 + 0.008
Class 0.05: 0.03 + 0.02
Display Resolution Class 0.01: 7-digit
Class 0.02: 7-digit
Class 0.05: 6-digit
Adjustment Fineness 0.001% × RG (Class 0.01)
0.002% × RG (Class 0.02 & 0.05)
Maximum Load Voltage 3.5 V
Ripple Coefficient ≤ 0.5%
Setup Time ≤ 3 seconds
Control Method Mobile measurement console + host PC control software
Protection Features Open-circuit, overload and overheating protection

Sensor Supply & Measurement Module

Parameter Specification
Voltage Measurement Range 100 mV, 1 V, 10 V (manual/auto shifting)
Voltage Measurement Scope ± (10 mV ~ 12 V)
Current Measurement Range 10 mA, 100 mA, 1 A (manual/auto shifting)
Current Measurement Scope ± (1 mA ~ 1.1 A)
Measurement Uncertainty (k=2) 0.003% × RD + 0.002% × RG
Sensor Power Output DC ± (5.0 V ~ 50.0 V), max load 1 A
Power Supply Accuracy Voltage/Current: ±0.2%, Power: ±0.5%
Temperature Coefficient ≤ 5 ppm/°C (0°C ~ 40°C)
Protection Short-circuit, overload & thermal protection
Optional AC Supply AC 220V (custom)

Optional High-Frequency Constant Current Source

Parameter Specification
Current Output Range 1 mA ~ 10.5 A
Frequency Range DC, 10 Hz ~ 1 MHz
Short-term Stability DC: 0.005%/min
Measurement Uncertainty (k=2) 10 kHz: 0.01%
100 kHz: 0.05%
1 MHz: 0.1%
Maximum Load Voltage DC: 0.02%, AC: 0.08% ~ 0.5%
Application Dynamic response testing & high-frequency calibration

Note: RD = Reading Value, RG = Range Value.