TK6800 Transformer Comprehensive Characteristic
TK6800 Transformer Comprehensive Characteristic

TK6800 Transformer Comprehensive Characteristic

TK6800 is a specialized calibration device designed for transformer testers. It provides precise calibration for a wide range of transformer testing equipment, including no-load loss testers, capacity testers, and short-circuit impedance testers. The calibration process complies with the reference standard DL/T 1256-2013 — General Specification of Transformer Tester for No-load Loss and Load Loss, ensuring reliable and traceable measurements for professional testing environments.

Three-phase Voltage Output

Parameter Specification
Voltage Range 10 V
Resolution 0.1 mV
Short-term Stability (%/min) 0.005
Measurement Uncertainty (k=2)
(ppm × RD + ppm × RG)
120 + 80
Maximum Load 10 mA

Three-phase Current Measurement

Current Range Resolution Measurement Uncertainty (k=2)
(ppm × RD + ppm × RG)
100 mA 1 μA 120 + 80
1 A 10 μA 120 + 80
5 A 10 μA 120 + 80
10 A 0.1 mA 120 + 80

No-load Loss Test — Three-phase Voltage Output

Voltage Range Resolution Short-term Stability (%/min) Measurement Uncertainty (k=2)
(ppm × RD + ppm × RG)
Maximum Load
60 V 0.1 mV 0.005 120 + 80 25 VA
120 V 1 mV 0.005 120 + 80 25 VA
240 V 1 mV 0.005 120 + 80 25 VA
480 V 1 mV 0.005 120 + 80 25 VA
720 V 1 mV 0.005 120 + 80 25 VA

Note: RD = Reading Value, RG = Range Value.